Search results for " Addition-polymerized silicone"

showing 2 items of 2 documents

Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

2009

The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recover…

Settore MED/07 - Microbiologia E Microbiologia ClinicaStaphylococcus aureusPolyether Addition-polymerized silicone Glutaraldehyde Quaternary ammonium compounds DisinfectionDental Impression MaterialsColony Count MicrobialDental DisinfectantsDisinfectionQuaternary Ammonium CompoundsResins SyntheticSettore MED/28 - Malattie OdontostomatologicheGlutaralBiofilmsCandida albicansMaterials TestingPseudomonas aeruginosaSilicone ElastomersEquipment Contamination
researchProduct

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials

2008

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…

medicine.medical_specialtyTime FactorsMaterials scienceSurface PropertiesDisinfectantDentistryimpression materials disinfectants dimensional stability disinfection polyether addition-polymerized siliconeElastomerSilicone rubberchemistry.chemical_compoundSettore MED/28 - Malattie OdontostomatologicheImmersionMaterials TestingmedicineImmersion (virtual reality)HumansGeneral Dentistrybusiness.industryDental Impression MaterialsDental DisinfectantsAmmonium compoundsSurgeryImpressionDisinfectionQuaternary Ammonium CompoundsResins SyntheticElastomerschemistryGlutaralSilicone ElastomersDental impression materialGlutaraldehydebusiness
researchProduct